Compressor Application Manual
8
Dehumidifier that works at an evaporator
temperature of over 0
o
C (32
o
F).
Heat absorption by the refrigerant will
depend on the evaporator temperature.
A certain pressure corresponds to a
certain temperature in the evaporator.
The gas density is higher at low
temperatures and, therefore, only a small
quantity of heat may be absorbed during
evaporation. If there is evaporation at a
higher temperature, for instance, 0
o
C
(32
o
F), the pressure and density will
increase and more heat will be absorbed.
For this reason, we can conclude that
the work required by the motor in a
compressor for a high evaporation
temperature will be more than that
required by the same compressor at a
low evaporation temperature.
Consequently, motors to be used in high
evaporation pressure systems must have
a higher operating torque.
The compressors can be classified
according to their use as follows:
HBP – High Back Pressure
High evaporation temperature
MBP – Medium Back Pressure
Medium evaporation temperature
LBP – Low Back Pressure
Low evaporation temperature
III